Real-Time Building Management
Understand Your Building's Energy Use

“You can’t manage what you don’t measure” is a phase applicable to many things in today’s world, but maybe none as impactful to the bottom line as measuring the performance of a building. A building is a living organism with many systems and machines running around the clock to produce products, manage data, and bring comfort to employees and customers. Energy monitoring is a powerful tool, giving building owners, managers, and tenants insight to where energy is consumed so action can be taken.

setra-systems-power-meters

Submetering Simplified



Setra Power Meter

setra-systems-power-meters

Available in 3, 12, and 48 load options. The Power Meter from Setra is a networked revenue-grade power meter built on a versatile and powerful platform designed to meet the high demands for any submetering application.

Patrol Flex Coil

Rogo_Coils_Patrol_Flex_NB

Offered in 12”, 24” and 36” lengths, the Patrol Flex Coil is the most accurate Rogowski Coil in submetering.

UL 2808 Split-Core CTs

ul-2808-split-core-current-transformers-1

Setra’s Split-Core current transformers provide a high accuracy current measurement over a wide dynamic sensing range for power metering applications. UL 2808 Certified

 




Quick & Easy Configuration via Setra Web Portal
  • Setup before getting to the jobsite using USB
  • Eliminate PPE, no need for setup in live enclosure
  • Clone meter setup to speed up next meter configuration
  • Download data for analysis or record keeping

power-meter-software

 

Setra_Power_Meter-01

 



Dual Voltage Inputs - Two Meters in One
  • Lower the cost per metering point
  • Measure two different services in one meter
  • Collect Data from Lighting loads & chillers on the same meter
  • Dual Voltage comes standard on SPM12 & SPM48 models


Minimize Conduit Spend & Labor
  • Housing rotates for straight conduit runs
  • Measure two different services in one meter
  • Collect Data from Lighting loads & chillers on the same meter
  • Dual Voltage comes standard on SPM12 & SPM48 models

conduit

 

energy-management-options

 



With so many to pick from, choose the one that makes it easy
  • Only three Power Meter SKU’s to choose from
  • Every meter measures up to 600 VAC
  • Easy to stock & quick delivery
  • Patrol Flex CT’s take the guesswork out of amperage

Rethink the Way Metering is Done

Whether called Multi-Load, Multi Circuit, Multi Channel or even Branch Circuit energy metering, Setra’s line of power meters lower the cost per metering point and measures with more granularity than other metering solutions on the market.​

  • Measure two different service levels with Dual Voltage inputs on the 12 or 48 Load meters)​
  • Any combination of single, dual, or three-phase loads up to the CT count of the meter​
  • Intuitively configure any application with on-board configuration portal

Measure More... For Less

measure-more-for-less

 

 




How the Meter Works

power-meter-software

Configure

Utilize the built-in configuration portal to easily map out what’s being measured to support any energy management strategy

connect-power-meter

Connect

Wire the voltage service lines, current transformers, pule I/O and communications wiring to the meter

power-meter-collect

Collect

Leverage the available BACnet or Modbus communications protocol to tie the meter into any existing or new EMS or BAS within the application

Looking for guidance? Let us help you get started.