Hot-Wire to Setra FLEX™ Conversion Kit

  • Room Pressure Monitor Hot-Wire Replacement Kit
  • Replace Old

Setra FLEX Hot-Wire Replacement Kit Logo

No Construction - Installs in Minutes - Replaces "8630" Units

GET RID OF OLD HOT-WIRE THROUGH-THE-WALL (TTW) TECHNOLOGY! The Setra FLEX™ Hot-wire Conversion Kit is designed to replace common Through-the-Wall (TTW) anemometer-based room pressure monitors with reliable capacitive sensing technology from Setra FLEX. The kit includes everything required for upgrading obsolete, high maintenance room pressure monitor technology. This kit can completely replace outdated, discontinued "8630" room pressure monitors with new, better technology.

Hot-Wire Replacement Kit Badges


Request Quote Button Example
No construction required for install

The complete kit can be installed in minutes and requires no wiring or wall modifications; all you need is just a ladder and screw driver. First, remove the existing sensor covers and replace them with Setra’s sensor. Next, connect using existing wires. Then, remove the legacy monitor and replace with Setra FLEX. Connect using existing wires and power, configure FLEX and you’re done!


Low-maintenance & contaminant-free sensing technology

Through-the-Wall (TTW) anemometer-based pressure monitors are prone to attract dirt and contaminants which can easily clog the sensing equipment, causing false alarms and unreliable readings. Setra’s capacitive pressure transducers are dead-ended sensors, which means there is no air flowing through pressure tubing. Our proprietary variable capacitance transducer requires no maintenance or cleaning. Re-zero can be done on the Setra FLEX touch screen and sensor calibration can be performed if the application requires it.

The Setra FLEX unit includes a brilliant 7” touch screen display, configurable visual and audible alarming, isolation and non-isolation modes, alarm delay, key switch input, and control operation for VAV dampers. Multiple units can be easily configured using Setra’s USB cloning feature.

More information about Setra FLEX™ Environmental Monitor can be found at www.setra.com/setra-flex.



Dirty probe sensor in a room pressure monitor




Features
  • Complete room pressure monitor kit to replace existing installations of hot-wire anemometer sensors
  • Attaches to existing sensor housing and wall box
  • No construction necessary; installs in minutes
  • Includes AHR Innovation Award-winning Setra FLEX™
  • Includes the no-maintenance Setra sensor
  • Specifications match or exceed existing legacy monitors
  • Required tools: a ladder & screw driver
  • No cutting into walls and no pulling wires
  • Replace obsolete "8630" units in minutes
Included in the kit
  • Setra FLEX-RM or FLEX-RC with 7” display
  • A sensor housing kit that attaches to the existing through-the-wall sensor assembly and includes Setra’s proprietary dead-ended variable capacitance pressure sensing element
  • A surface-mount adapter housing for Setra FLEX that can fit over existing wall boxes

Related Products
Setra FLEX Room Pressure Monitor
Setra FLEX™ Room Pressure Monitor

Setra FLEX™ provides a flexible room environmental control and monitoring solution in a simple-to-use package. The unit supports 3 rooms, monitoring up to 6 parameters per room.

Setra's Model SRPM Room Pressure Monitor
Model SRPM Room Pressure Monitor

The SRPM is Setra’s standard single room BACnet capable room pressure monitor for measuring low differential pressure in critical applications.

Model_SRH200-thumb-1

 

SRH200 Humidity & Temperature Transmitter

Specially designed for HVAC, the SRH200 sensor by Setra is a cost effective, highly accurate and reliable solution for measuring relative air humidity and temperature.